190 Programming Commands
MAXSPD Trajectory Parameter
ACTION: Sets or returns the maximum allowed speed of the specified axis.
PROGRAM SYNTAX: MAXSPD(axis)=number cr
MAXSPD=number1, ... , number 8 cr
MAXSPD(axis) cr
MAXSPD cr
REMARKS: See Programming Command MAXSPD.
EXAMPLES: MAXSPD(3)=50
Sets the maximum speed for axis 3 to 50 units/second.
MAXSPD=50,,60
Sets the maximum speed for axis 1 to 50 units/second, axis 2 is un-
changed and axis 3 to 60 units/second.
MAXSPD(2)
Returns the maximum speed for axis 2.
MAXSPD
Returns the maximum speed for all assigned axes.
MOVE Motion Parameter
ACTION: Initiates a non-coordinated move.
PROGRAM SYNTAX: MOVE(axis)=number cr
MOVE=number1, ... , number8
REMARKS: See Programming Command MOVE.
EXAMPLES: POSMODE(1,3)=0,0
MOVE(3)=-2
axis 3 moves -2 units.
MOVE=1,,3
axis 1 moves +1 units, and axis 3 moves +3 units.