Programming Commands 183
FOLERR Motion Parameter
ACTION: Sets or returns the maximum position error allowed during motion, herein
referred to as "following error."
COMMAND SYNTAX: FOLERR(axis)=number cr
FOLERR=number1, number2, . . . , number8 cr
FOLERR(axis) cr
FOLERR cr
REMARKS: See Programming Command FOLERR.
Note: ENCFOL can be substituted for FOLERR.
EXAMPLES: FOLERR(2)=.4
Sets the following error of axis 2 to .4 units.
FOLERR=.4,, .3
Sets the following error of axis 1 to .4 units, axis 2 is unchanged and axis
3 is set to .3 units.
FOLERR(2)
Returns the current following error set for axis 2.
FOLERR
Returns the current following error set for all assigned axes.
FREE Miscellaneous Command
ACTION: Transfers the free space, in sectors, available in non-volatile memory.
COMMAND SYNTAX: FREE cr
REMARKS: A sector consists of 128 bytes of non-volatile memory. With no pro-
gram(s) loaded, the free space value is 2044 sectors.
The transfer format is:
free space = nnnncr